Battery Boosted Charging

The new ADVANTICS ADB Series is a system of stackable power modules for DC Fast Charge stations supporting CCS, NACS, and MCS charging standards, as well as various energy storage system applications and industrial power systems. Its no-compromises design is fully sealed and liquid cooled to ensure the highest levels of reliability in any operating environment. From corrosive coastal regions, to the humid tropics, to scorching hot deserts, to the frigid arctic, it can handle them all.
In order to streamline product development, the ADB series contains integrated features such as AC mains management and grid code integration. It features an extremely wide output voltage/current range, reactive power control, and dual output switch gear to enable power shuffling or multiple dispensers.
The integrated gateway allows for easy firmware update, isolated CAN bus interface, parallel stack management and cybersecurity.
As a vertically integrated company, we don’t rely on 3rd party black boxes and are therefore able to give our customers full control of their system.
All of ADVANTICS products are proudly designed and manufactured in the European Union.
Bidirectional AC/DC power module
SiC technology
Reinforced isolation
97 % peak efficiency, wide power range
Universal AC input 400/480 VAC, 50/60 Hz
Wide output range, 0 - 950 V, ±135 A
Watercooling, no air circulation needed
IP67 sealed design
CAN bus control, HW interlock
Can be easily paralleled to MW levels
Integrated input and output fusing
Integrated relays and output contactors
Intelligent dual DC output for 2-pistol systems
Fast DC charging supporting CCS1, CCS2, NACS and CHAdeMO
Uninterruptible power supply (UPS) for data centres
Energy Storage Systems
Vehicle-to-Grid (V2G) systems
AC and DC microgrids
Onboard charging for off-highway and heavy duty machinery
EV and charge simulators
Laboratory bidirectional power supply
Harsh environments (marine, coastal areas, mining)
AC side (mains)
Rated AC voltage (L-L)
380 - 480 Vrms
Rated AC frequency
50 / 60 Hz
Maximum AC current
±75 Arms per phase
Power factor (PF)
≥0.99
Total Harmonic Distortion THDi
≤5 %, for loads above 20 %
Reactive Power Control
±0.9 inductive-capacitive
Wiring
L1, L2, L3, (no Neutral)
Startup
Internal soft start
Inrush current
Less than nominal current
Phase to PE separation
Basic isolation
Protection
Overvoltage, undervoltage, overcurrent, overtemperature
Fusing
Yes, UL/IEC rated
Overvoltage category
OVC2
Grid generation
Forming, following, microgrid
Connectors AC
3x (L1,L2,L3) RADSOK Size 5.7 mm Amphenol SurLock Plus (SLP-HIR-A)
DC side (output - bidirectional)
Voltage range
0 - 950 V
Current
±135 A (bidirectional), limited by power envelope
Max power
50 kW
Current measurement accuracy
±1 % of full-scale
Voltage measurement accuracy
±1 % of full-scale
Primary-secondary separation
Reinforced isolation
Ripple voltage/current
Fulfills IEC 61851-23
Fusing
Yes, on positive line, UL/IEC rated
Output contactors
Yes
Protection
Overvoltage, undervoltage, overcurrent, overtemperature
Connectors DC
2x RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)
Low voltage and communication
Communication interface
CAN 2.0B
External control power supply voltage
24 nominal (20 - 28) V
Control power consumption
50 W
Standby power consumption
5 W
Isolation concept
CAN and 24 V isolated from PE CAN bus isolated from 24 V Basic isolation, reinforced towards HV
Connectors
2x for CAN, 1x for power
Paralleling of converters
Up to 120 units in parallel
Mechanical
Dimensions
700 x 400 x 165 mm
Weight
45.3 kg
Cooling
50/50 Water Ethylene Glycol Mix
Noise
Watercooled, small internal fan
Mounting
4U rack, or custom brackets
Environment
Operating temperature range
-40 to 70 °C, derating applies
Ingress protection code
IP67
Allowed pollution degree
3 external environment
Altitude
3000 m
Shock
Pending
Standards
Designed to following standards
IEC 61851-1, 61851-23 ED2, IEC 62477-1, UL 2202, UL 1741
Electromagnetics compatibility
EMC class B possible with an external filter
Design and Manufacturing
EU