1. Home
  2. Products
  3. 50 kW AC/DC Power Converter V2G

Overview

The new ADVANTICS ADB Series is a system of stackable power modules for DC Fast Charge stations supporting CCS, NACS, and MCS charging standards, as well as various energy storage system applications and industrial power systems. Its no-compromises design is fully sealed and liquid cooled to ensure the highest levels of reliability in any operating environment. From corrosive coastal regions, to the humid tropics, to scorching hot deserts, to the frigid arctic, it can handle them all.

In order to streamline product development, the ADB series contains integrated features such as AC mains management and grid code integration. It features an extremely wide output voltage/current range, reactive power control, and dual output switch gear to enable power shuffling or multiple dispensers.

The integrated gateway allows for easy firmware update, isolated CAN bus interface, parallel stack management and cybersecurity.

As a vertically integrated company, we don’t rely on 3rd party black boxes and are therefore able to give our customers full control of their system.

All of ADVANTICS products are proudly designed and manufactured in the European Union.

Characteristics

  • Bidirectional AC/DC power module

  • SiC technology

  • Reinforced isolation

  • 97 % peak efficiency, wide power range

  • Universal AC input 400/480 VAC, 50/60 Hz

  • Wide output range, 0 - 950 V, ±135 A

  • Watercooling, no air circulation needed

  • IP67 sealed design

  • CAN bus control, HW interlock

  • Can be easily paralleled to MW levels

  • Integrated input and output fusing

  • Integrated relays and output contactors

  • Intelligent dual DC output for 2-pistol systems

Applications

  • Fast DC charging supporting CCS1, CCS2, NACS and CHAdeMO

  • Uninterruptible power supply (UPS) for data centres

  • Energy Storage Systems

  • Vehicle-to-Grid (V2G) systems

  • AC and DC microgrids

  • Onboard charging for off-highway and heavy duty machinery

  • EV and charge simulators

  • Laboratory bidirectional power supply

  • Harsh environments (marine, coastal areas, mining)

Technical Data

AC side (mains)

Rated AC voltage (L-L)

380 - 480 Vrms

Rated AC frequency

50 / 60 Hz

Maximum AC current

±75 Arms per phase

Power factor (PF)

≥0.99

Total Harmonic Distortion THDi

≤5 %, for loads above 20 %

Reactive Power Control

±0.9 inductive-capacitive

Wiring

L1, L2, L3, (no Neutral)

Startup

Internal soft start

Inrush current

Less than nominal current

Phase to PE separation

Basic isolation

Protection

Overvoltage, undervoltage, overcurrent, overtemperature

Fusing

Yes, UL/IEC rated

Overvoltage category

OVC2

Grid generation

Forming, following, microgrid

Connectors AC

3x (L1,L2,L3) RADSOK Size 5.7 mm Amphenol SurLock Plus (SLP-HIR-A)

DC side (output - bidirectional)

Voltage range

0 - 950 V

Current

±135 A (bidirectional), limited by power envelope

Max power

50 kW

Current measurement accuracy

±1 % of full-scale

Voltage measurement accuracy

±1 % of full-scale

Primary-secondary separation

Reinforced isolation

Ripple voltage/current

Fulfills IEC 61851-23

Fusing

Yes, on positive line, UL/IEC rated

Output contactors

Yes

Protection

Overvoltage, undervoltage, overcurrent, overtemperature

Connectors DC

2x RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)

Low voltage and communication

Communication interface

CAN 2.0B

External control power supply voltage

24 nominal (20 - 28) V

Control power consumption

50 W

Standby power consumption

5 W

Isolation concept

CAN and 24 V isolated from PE CAN bus isolated from 24 V Basic isolation, reinforced towards HV

Connectors

2x for CAN, 1x for power

Paralleling of converters

Up to 120 units in parallel

Mechanical

Dimensions

700 x 400 x 165 mm

Weight

45.3 kg

Cooling

50/50 Water Ethylene Glycol Mix

Noise

Watercooled, small internal fan

Mounting

4U rack, or custom brackets

Environment

Operating temperature range

-40 to 70 °C, derating applies

Ingress protection code

IP67

Allowed pollution degree

3 external environment

Altitude

3000 m

Shock

Pending

Standards

Designed to following standards

IEC 61851-1, 61851-23 ED2, IEC 62477-1, UL 2202, UL 1741

Electromagnetics compatibility

EMC class B possible with an external filter

Design and Manufacturing

EU

Please note that the technical data presented on the website is for reference only and may be subject to change without prior notice.