Marine: electrification’s next frontier

PUBLISHED
Glaciers sculpted Norway’s coastline into deep fjords framed by sheer cliffs, creating a shoreline that seems to grow longer the closer you look. For generations, life along these shores has followed the water—a source of food and commerce, a place to explore, and a connection between communities divided by rugged terrain. Where roads must wind around the landscape, boats can take a more direct path.
It is no coincidence why the marine industry is massive in the region.
Working with nature here is much more efficient than working against it. In 2024, Norway generated 98% of its electricity predominantly from hydropower and the rest from solar – well above the global average of 41%. Data released by the Norwegian Road Federation (OFV) indicates a near-total transition to electric mobility with 97.6% of all new passenger car registrations in Norway. Remember that this winter when the media, politicians or your local neighbour are sensationalizing that these cars do not work in the cold, it does not appear to be a problem here.
The physics is a little different for boats and there is no magic. The energy density of batteries is not high enough to replace transatlantic travel on a single tank, sometimes we forget how amazing that is. It also does not come for free. The cost of diesel can be as high as 5 times more than electricity, and on heavy usage these costs add up. Add the greater reliability and improvements that come with simpler machines and the case for shifting towards electrified boats and marine electrification becomes even stronger.
There are many applications for electrified ships that have already established product market fit.
-
Ferries are used in public transport, going town to town carrying people and/or their cars with planned fast charging at every stop to sustain the full day. This is typically delivered by an on-shore charging station at each terminal. High-power systems often use automated plug-in connectors or robotic charging arms so the vessel can connect within seconds of mooring, sometimes paired with automated mooring. Because grid connections at small ports can be weak, many sites add a shore-side battery buffer (battery energy storage system, BESS) that charges slowly from the grid and discharges quickly into the ferry. The ferry itself is usually a fully electric (battery-electric) vessel, and the high-voltage connection follows the IEC/IEEE 80005-1 high-voltage shore connection (HVSC) standard.
-
Off-shore work sites may require traveling out to a site, performing work all day, and returning back in the evening. Vessels in this segment include crew transfer vessels (CTVs) and service operation vessels (SOVs) supporting offshore wind farms. They usually rely on overnight or depot charging at port, and may use off-shore charging from a charging buoy or directly from a wind turbine or offshore substation to extend range during the day. Many are hybrid or plug-in hybrid vessels with a diesel or methanol range extender for longer transits or bad weather. While on station, power for hotel loads (lighting, HVAC, crew facilities) and dynamic positioning (DP) is a major part of the energy demand.
-
Tug boats operate regionally, moving barges or maneuvering cargo ships while in port. Their duty cycle is short, high-power bursts measured in bollard pull, followed by long idle periods, which suits battery-electric or hybrid diesel-electric designs. Charging is usually depot charging at the tug’s home berth between jobs or overnight, using shore power from an on-shore charging station. Smaller installations may use on-board charging, where AC shore power is converted by a charger installed on the vessel, while larger systems use off-board (DC) charging, where the conversion happens on shore and DC power is delivered directly to the batteries. Lower-power connections follow IEC/IEEE 80005-3 low-voltage shore connection (LVSC).
The bottleneck has now moved to charging.
A heavy tug boat for example may have a 6 MWh battery. If you want to recharge that in an hour, that means you need a 6 MW charger (6000 kW). A very fast EV fast charger is still only at around 400 kW with BYD’s absurd flash charging reaching 1.5 MW for about 10 minutes. The order of magnitude makes it clear why normal EV charging standards fall short. That is why the industry has been adopting the Megawatt Charging System (MCS) – in its highest spec form MCS-R, it supports up to 1500 V and 4000 A or 6 MW, which is enough to recharge a heavy-duty tug boat during a lunch break.
To maintain a stable grid for everyone, the best way to serve these charging stations is to add battery buffering. The batteries can work with the grid and absorb intermittent renewable energy as it is being generated, store it, and release it on command. Notably, at these voltage and power levels, there are also new safety concerns. Typical grid connection installations look for “fault current” ratings during the design stage, if you have two multi-MWh batteries connected in parallel with a fault, the amount of potential energy that could be released in a short circuit might make the sun look dim. Centralizing protection circuits also creates for very large and expensive switch gear.
A rather more elegant solution is to solve the problem in smaller pieces using galvanically isolated DC/DC converters for connecting these systems.
ADVANTICS module, ADB-PC-DC01, implements a dual active bridge (DAB) for isolation. This device converts DC to AC, through a transformer, and back to DC. Transformers only work if the current is alternating , creating alternating magnetic fields. So, in the event of an uncontrolled DC fault, a transformer physically cannot couple the current from one side to the other, because they rely on a changing magnetic field to transfer energy, as described by Faraday’s law.
The inherent ability to block DC fault current is a well-established advantage of AC transformers and has been used since the earliest days of transformer technology. The other major benefit of the DAB architecture and power electronics over a passive transformer is the overall size, weight and cost of the core materials. Grid-coupled transformers operate at 50 Hz, which means for every cycle (1 second/50 cycles = 0.02 seconds/cycle), they are sized by the amount of energy needed to store in the cores. Utilizing high-speed Silicon Carbide power electronics, the DAB design is able to push that frequency up to 300 kHz (1 second /300,000 cycles = 0.000003 seconds/cycle). A simple dimensional analysis shows that the core design can shrink substantially. Internal analysis shows about a 50 to 100 times reduction in size, plus improved efficiency with peak around 98.5% across this conversion stage. Our module, ADM-PC-BI25, provides galvanic isolation without requiring a large mains frequency transformer, and delivers up to 50 kW power with 98.7% peak efficiency.
This improvement in safety and reduced components enables new business models for charging as well.
Some companies have started creating charging barges, so instead of fast chargers installed permanently on the dock, these vessels can be pulled around from dock to dock as a refueling service. Every kilogram of transformer removed can instead be replaced with more energy storage, increasing the barge’s delivery capacity and efficiency.
Galvanic isolation also helps keep batteries separated. At the MWh scale of both charging systems and vessels, these typically turn into parallel battery strings for both safety and redundancy. In the unfortunate event of an issue, strings can be disconnected and isolated while everything keeps operating. There is also the added benefit of isolation monitoring as with galvanic isolation each string can have its own isolation monitoring and faults can be traced to the source.
Not every recharge needs a fast charge. Some of these boats have a long dwell time at the docks overnight and can benefit from the shore power available. In these instances, they benefit from the lowest charging costs by charging slowly, similar to how most EVs are charged overnight at home. ADVANTICS offers multiple options in either 50 kW or 100 kW blocks and can scale up from there.
Finally, marine’s highly corrosive environments are difficult to operate in. Any air-cooled power electronics have a short lifespan before failure once filled with salt fog. This is why all power modules in our ADB series are fully sealed and liquid cooled.
Failures are not just about the cost of the equipment, but more about the cost of the impacted operation. If a tug boat cannot move a container ship in or out of a port, it could cost thousands of euros per hour of loss. As ports and vessels become increasingly electrified for efficient, robust and sustainable operation, highly reliable power systems will become an essential part of the infrastructure that keeps global trade moving. The opportunity is not only to electrify marine transport, but to build power systems that are smaller, more efficient and reliable enough to support the next generation of maritime operations.
The ADVANTICS Advantage
ADVANTICS supplies the power conversion and charge controllers for grid-connected and battery-buffered marine charging.
A 100 kW bidirectional, galvanically isolated DC/DC converter operating up to 1500 V. Fully sealed and liquid cooled, with modules that can be paralleled for megawatt charging. It transfers energy from a compatible DC supply to the vessel battery.
A 100 kW bidirectional AC/DC converter that connects the shore DC bus to the electric grid. Paired with DC01, it provides the grid interface for an isolated charging system.
An all-in-one solution for mid size ships as a 50 kW Isolated bidirectional AC/DC converter that connects the shore AC grid to charge the battery.
A bidirectional isolated DC/DC converter providing galvanic isolation without requiring a large mains transformer, delivering up to 50 kW power with 98.7% peak efficiency.
An MCS-capable charging station controller that manages communication with the vessel and controls the charger’s power modules.
An MCS-capable charge controller for the vessel, handling communication with the shore charger over 10BASE-T1S Ethernet.