Powering Data Centres

The new ADVANTICS ADB Series is a system of stackable power modules for DC Fast Charge stations supporting CCS, NACS, and MCS charging standards, as well as various energy storage system applications and industrial power systems. Its no-compromises design is fully sealed and liquid cooled to ensure the highest levels of reliability in any operating environment. From corrosive coastal regions, to the humid tropics, to scorching hot deserts, to the frigid arctic, it can handle them all.
In order to streamline product development, the 100 kW AC/DC frontend contains integrated features such as AC mains management and grid code integration. It features an extremely wide output voltage/current range, reactive power control, common DC link bus for distributed DC-coupled systems.
The integrated gateway allows for easy firmware update, isolated CAN bus interface, parallel stack management and cybersecurity.
As a vertically integrated company, we don’t rely on 3rd party black boxes and are therefore able to give our customers full control of their system.
All of ADVANTICS products are proudly designed and manufactured in the European Union.
Bidirectional AC/DC Active Frontend (PFC)
SiC technology
Bidirectional, low current distortion (THDi)
98.5 % peak efficiency
Universal AC input 208-480 VAC, 50/60 Hz
Up to 950 V DC link
Watercooling, no air circulation needed
IP67 sealed design
CAN bus control, HW interlock
Can be easily paralleled to MW levels
Integrated input and output fusing
Integrated mains relays
Intelligent droop technology for DC link paralleling
Electric Vehicle DC chargers
CCS1, CCS2, NACS, MCS, CHAdeMO
Energy Storage Systems
Industrial PFC rectifiers
V2G (Vehicle 2 Grid) systems
AC and DC microgrids
Battery assisted charging
Onboard charging for off-highway and heavy duty machinery
EV and charge simulators
Laboratory bi-directional power suppliers
Harsh environments (marine, coastal areas, mining)
AC side (mains)
Rated AC Voltage (L-L)
208 - 480 Vrms, reduced power below 380 Vrms
Rated AC frequency
50 / 60 Hz
Maximum AC current
±150 Arms per phase
Power Factor (PF)
≥0.99
Total Harmonic Distortion THDi
≤5 %, for loads above 20 %
Reactive Power Control
±0.9 inductive-capacitive
Wiring
L1, L2, L3, (no Neutral)
Startup
Internal soft start
Inrush current
Less than nominal current
Phase to PE separation
Basic Isolation
Protection
Overvoltage Undervoltage Overcurrent Overtemperature
Fusing
Yes, UL/IEC rated
Overvoltage category
OVC-II
Grid generation
Forming, following, microgrid
Connectors AC
3x RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)
DC side (output - bidirectional)
Voltage range
650 - 950 V (min DC voltage depends on the mains voltage)
Current
±170 A (bidirectional), limited by power envelope
Max power
100 kW
Current measurement accuracy
±1 % of full-scale
Voltage measurement accuracy
±1 % of full-scale
Primary-secondary separation
Non-isolated
Fusing
Yes, on positive line, UL/IEC rated
Output contactors
No
Protection
Overvoltage, undervoltage, overcurrent, overtemperature
Connectors DC
2x port A, RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)
Low voltage and communication
Communication interface
CAN 2.0B
External control power supply voltage
24 nominal (20-28) V
Control power consumption
50 W
Standby power consumption
5 W
Isolation concept
CAN and 24 V isolated from PE CAN bus isolated from 24 V Basic isolation, reinforced towards HV
Connectors
2x for CAN, 1x for power
Paralleling of converters
Up to 120 units in parallel
Mechanical
Dimensions
700 x 400 x 165 mm
Weight
43 kg
Cooling
50/50 Water Ethylene Glycol Mix
Noise
No fan noise, watercooled
Mounting
4U rack, or custom brackets
Environment
Operating temperature range
-40 to 70 °C derating applies
Ingress protection code
IP67
Allowed pollution degree
3 external environment
Altitude
3000 m
Shock
Pending
Vibrations
Designed for harsh environments
Standards
Designed to following standards
IEC 61851-1, 61851-23 ED2, IEC 62477-1, UL2202, UL1741
Grid Code Support
EN50549-1, IEEE 1547, VDE-AR-N 4100, UK G99, AS 4777.2
Clearance distance
Min. 2 mm for all barriers
Creepage distance
Min. 2 mm for Line to Case Min. 2.5 mm for DC to Case
HV to Case
Basic Insulation Fault Protection 2500 V impulse
HV to Control
Basic Insulation Fault Protection 2500 V impulse
Electromagnetics compatibility
EMC class B with an external filter
Overvoltage Category
OVC2 up to 3000 m
General
Documentation
Publicly available online
Support
ADVANTICS Helpdesk included
Design and Manufacturing
EU