Overview

The new ADVANTICS ADB Series is a system of stackable power modules for DC Fast Charge stations supporting CCS, NACS, and MCS charging standards, as well as various energy storage system applications and industrial power systems. Its no-compromises design is fully sealed and liquid cooled to ensure the highest levels of reliability in any operating environment. From corrosive coastal regions, to the humid tropics, to scorching hot deserts, to the frigid arctic, it can handle them all.

In order to streamline product development, the 100 kW AC/DC frontend contains integrated features such as AC mains management and grid code integration. It features an extremely wide output voltage/current range, reactive power control, common DC link bus for distributed DC-coupled systems.

The integrated gateway allows for easy firmware update, isolated CAN bus interface, parallel stack management and cybersecurity.

As a vertically integrated company, we don’t rely on 3rd party black boxes and are therefore able to give our customers full control of their system.

All of ADVANTICS products are proudly designed and manufactured in the European Union.

Characteristics

  • Bidirectional AC/DC Active Frontend (PFC)

  • SiC technology

  • Bidirectional, low current distortion (THDi)

  • 98.5 % peak efficiency

  • Universal AC input 208-480 VAC, 50/60 Hz

  • Up to 950 V DC link

  • Watercooling, no air circulation needed

  • IP67 sealed design

  • CAN bus control, HW interlock

  • Can be easily paralleled to MW levels

  • Integrated input and output fusing

  • Integrated mains relays

  • Intelligent droop technology for DC link paralleling

Applications

  • Electric Vehicle DC chargers

  • CCS1, CCS2, NACS, MCS, CHAdeMO

  • Energy Storage Systems

  • Industrial PFC rectifiers

  • V2G (Vehicle 2 Grid) systems

  • AC and DC microgrids

  • Battery assisted charging

  • Onboard charging for off-highway and heavy duty machinery

  • EV and charge simulators

  • Laboratory bi-directional power suppliers

  • Harsh environments (marine, coastal areas, mining)

Technical Data

AC side (mains)

Rated AC Voltage (L-L)

208 - 480 Vrms, reduced power below 380 Vrms

Rated AC frequency

50 / 60 Hz

Maximum AC current

±150 Arms per phase

Power Factor (PF)

≥0.99

Total Harmonic Distortion THDi

≤5 %, for loads above 20 %

Reactive Power Control

±0.9 inductive-capacitive

Wiring

L1, L2, L3, (no Neutral)

Startup

Internal soft start

Inrush current

Less than nominal current

Phase to PE separation

Basic Isolation

Protection

Overvoltage Undervoltage Overcurrent Overtemperature

Fusing

Yes, UL/IEC rated

Overvoltage category

OVC-II

Grid generation

Forming, following, microgrid

Connectors AC

3x RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)

DC side (output - bidirectional)

Voltage range

650 - 950 V (min DC voltage depends on the mains voltage)

Current

±170 A (bidirectional), limited by power envelope

Max power

100 kW

Current measurement accuracy

±1 % of full-scale

Voltage measurement accuracy

±1 % of full-scale

Primary-secondary separation

Non-isolated

Fusing

Yes, on positive line, UL/IEC rated

Output contactors

No

Protection

Overvoltage, undervoltage, overcurrent, overtemperature

Connectors DC

2x port A, RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)

Low voltage and communication

Communication interface

CAN 2.0B

External control power supply voltage

24 nominal (20-28) V

Control power consumption

50 W

Standby power consumption

5 W

Isolation concept

CAN and 24 V isolated from PE CAN bus isolated from 24 V Basic isolation, reinforced towards HV

Connectors

2x for CAN, 1x for power

Paralleling of converters

Up to 120 units in parallel

Mechanical

Dimensions

700 x 400 x 165 mm

Weight

43 kg

Cooling

50/50 Water Ethylene Glycol Mix

Noise

No fan noise, watercooled

Mounting

4U rack, or custom brackets

Environment

Operating temperature range

-40 to 70 °C derating applies

Ingress protection code

IP67

Allowed pollution degree

3 external environment

Altitude

3000 m

Shock

Pending

Vibrations

Designed for harsh environments

Standards

Designed to following standards

IEC 61851-1, 61851-23 ED2, IEC 62477-1, UL2202, UL1741

Grid Code Support

EN50549-1, IEEE 1547, VDE-AR-N 4100, UK G99, AS 4777.2

Clearance distance

Min. 2 mm for all barriers

Creepage distance

Min. 2 mm for Line to Case Min. 2.5 mm for DC to Case

HV to Case

Basic Insulation Fault Protection 2500 V impulse

HV to Control

Basic Insulation Fault Protection 2500 V impulse

Electromagnetics compatibility

EMC class B with an external filter

Overvoltage Category

OVC2 up to 3000 m

General

Documentation

Publicly available online

Support

ADVANTICS Helpdesk included

Design and Manufacturing